HEAT INDEX WBGT METER-WBGT-2010SD

Compare
Category:

Description

FEATURES:
  • Introduction :WBGT ( wet-bulb globe temperature ) was developed as a monitoring basis at US military training camps
    and became widespread for the use in workplaces and sports situation It is suggested in the international standard ISO 7243, OSHA ( US Occupation Safety ),Japan Society for Occupational Health and the SMA Sports Medicine Australia ) in establishing the
    permissible heat exposure limits in health , sports or other physical activities.
  • Measurement :WBGT value ( Indoor/Outdoor Wet bulb globe temperature ), Black globe temperature, Humidity,
    Air temperature, Wet bulb temperature, Dew point Temp..
  • Adjustable WBGT alarm setting, if the WBGT value over the alarm threshold, the buzzer will sound along with the flashing Display.
  • Using to control and monitor of physical activity in hot environment to limit the danger of heat related injuries.
  • Globe temperature measurement use the Pt sensor,high accuracy
  • Fast humidity measuring response time
  • Direct measurement of the radiation effect with a brass black ball in 75 mm dia.
  • Sensor protecting mechanism.
  • Real time SD memory card Datalogger, it Built-in Clock and Calendar, real time data recorder , sampling time set from 1 second to 3600 seconds
  • Manual datalogger is available ( set the sampling time to 0 ), during execute the manual datalogger function, it can set the different position ( location ) No.( position 1 to position 99 )
  • Innovation and easy operation, computer is not need to setup extra software, after execute datalogger, just take away the SD card from the meter and plug in the SD card into the computer,it can down load the all the measured value with
    the time information ( year/month/date/hour/minute/second ) to the Excel directly, then user can make the further data or graphic analysis by themselves.
  • SD card capacity : 1 GB to 16 GB
  • LCD with green light backlight, easy reading.
  • Can default auto power off or manual power off.
  • Data hold, record max. and min. reading.
  • Microcomputer circuit, high accuracy.
  • Power by UM3/AA ( 1.5 V ) x 6 batteries or DC 9V adapter.
  • RS232/USB PC COMPUTER interface.
GENERAL SPECIFICATIONS
Circuit Custom one-chip of microprocessor LSI circuit
Display LCD size : 5.2 cm x 3.8 cm
LCD with green backlight ( ON/OFF ).
Measurement Wet bulb globe temperature ( WBGT )
@ Indoor/Outdoor
Black globe temperature ( TG )
Air temperature ( TA )
Wet bulb temperature ( WB )
Humidity
Dew point temperature
WBGT formula
Wet bulb
globe Temp
Indoor/Outdoor and no sun :
WBGT = ( 0.7 x WB ) + ( 0.3 x TG )
Outdoor and full sun :
WBGT = ( 0.7 x WB ) + ( 0.2 x TG ) + ( 0.1 x TA )
Datalogger
Sampling Time
Setting range
Auto:1 second to 3600 seconds
@ Sampling time can set to 1 second,
but memory data may loss.
Manual:Push the data logger button once will save data one time.
@ Set the sampling time to
0 second.
@ Manual mode, can also select the
1 to 99 position ( Location ) no.
Data error no 0.1% of total saved data max.
Memory Card SD memory card. 1 GB to 16 GB
Advanced setting
  • Set clock time ( Year/Month/Date,Hour/Minute/ Second )
  • Set WBGT alarm value
  • Decimal point of SD card setting
  • Auto power OFF management
  • Set beep Sound ON/OFF
  • Select the temperature unit to °C or °F .
  • Set sampling time
  • SD memory card Format
Data Hold Freeze the display reading.
Memory Recall Maximum & Minimum value.
Sampling Time of Display Approx. 1 second.
Data Output RS 232/USB PC computer interface.
Connect the optional RS232 cable
UPCB-02 will get the RS232 plug.
Connect the optional USB cable
USB-01 will get the USB plug.
Operating
Temperature
0 to 50 °C .
Operating
Humidity
Less than 85% R.H.
Power Supply A Alkaline or heavy duty DC 1.5 V battery
( UM3, AA ) x 6 PCs, or equivalent.
Power Current
  • Normal operation ( w/o SD card save
    data and LCD Backlight is OFF) :Approx. DC 5 mA.
  • When SD card save the data but and
    LCD Backlight is OFF) :
    Approx. DC 25 mA.
  • If LCD backlight on, the power
    consumption will increase approx.
    11 mA.
Weight 0.489 kg/1.08 LB.
Dimension Meter,177 x 68 x 45 mm
Black brass ball,(7.0 x 2.7x 1.9 inch)Round, 7.5 cm dia
Standard Accessories Included Instruction manual……………………….1 PC
Black brass ball ( with sensor )……. 1 PC
Soft carrying case, CA-05B…………….1 PC
Optional Accessories
  • SD Card ( 2 GB )
  • AC to DC 9V adapter.
  • USB cable, USB-01.
  • RS232 cable, UPCB-02.
  • Data Acquisition software,SW-U801-WIN.
  • Hard carrying case, CA-08,
    Size : 37 x 31 x 11.5 cm.
ELECTRICAL SPECIFICATIONS (23± 5 °C )
Wet bulb globe temperature ( WBGT )
Range °C Indoor
Outdoor
0 °C to 59 °C
0 °C to 56 °C
°F Indoor
Outdoor
32 to 138 °F
32 to 132 °F
Accuracy
-Indoor
°C ± 1 °C ( 15 to 59 °C )
± 1.5 °C ( Others )
°F ± 1.8 °F ( 59 to 138 °F )
± 2.7 °F ( Others )
Accuracy
-Outdoor
°C ± 1.5 °C ( 15 to 56 °C )
± 2 °C ( Others )
°F ± 2.7 °F ( 59 to 132 °F )
± 3.6 °F ( Others )
WBGT Formula :
Indoor
( Outdoor and no sun
WBGT= 0.7WB + 0.3TG
Outdoor
( Outdoor and full sun )
WBGT= 0.7WB + 0.2TG + 0.1TA
Air temperature ( TA )
Range °C 0 to 50 °C
°F 32 to 122 °F .
Resolution °C 0.1 °C
°F 0.1 °F
Accuracy
@ 15 to 40 °C
°C ± 0.8 °C
°F ± 1.5 °F
Black globe temperature ( TG )
Range °C 0 to 80 °C
°F 32 to 176 °F .
Resolution °C 0.1 °C
°F 0.1 °F
Accuracy
@ 15 to 40 °C
°C ± 0.6 °C
°F ± 1.1 °F
Air temperature ( TA )
Range °C 0 to 50 °C
°F 32 to 122 °F .
Resolution °C 0.1 °C
°F 0.1 °F
Accuracy
@ 15 to 40 °C
°C ± 0.8 °C
°F ± 1.5 °F
Humidity
Range 5 % to 95 % R.H.
Resolution 0.1 % R.H.
Accuracy ≧ 70% RH :
± (3% reading + 1% RH).
< 70% RH : ± 3% RH.
Air temperature ( TA )
Range °C 0 to 50 °C
°F 32 to 122 °F .
Resolution °C 0.1 °C
°F 0.1 °F
Accuracy
@ 15 to 40 °C
°C ± 0.8 °C
°F ± 1.5 °F
Dew Point Temp.
°C Range -25.3 °C to 48.9 °C
Resolution 0.1 °C
°F Range -13.5 °F to 120.1 °F .
Resolution 0.1 °F .
Remark :

  • Dew Point Temp. value is calculated from the
    Humidity/Air Temp. measurement automatically.
  • The Dew Point Temp. accuracy is sum accuracy value of Humidity & Air Temperature measurement..
Wet bulb Temp.
°C Range -21.6 °C to 50.0 °C
Resolution 0.1 °C
°F Range -6.9 °F to 122.0 °F .
Resolution 0.1 °F .
Remark :

  • Wet bulb display value is calculated from the
    Humidity/Air Temp. measurement automatically.
  • The Dew Point accuracy is sum accuracy value of
    Humidity & Air temperature measurement..
Recommendations to heat exposure level for working and physical activity.( Permissible heat exposure threshold limit )
Work/rest regimen( Each hour ) Light Moderate Heavy
Continuous work 30 °C( 86 °F ) 26.7 °C( 80 °F ) 25 °C( 77 °F )
75% work, 25% rest 30.6 °C( 87 °F ) 28 °C( 82 °F ) 25.9 °C( 78 °F )
50% work, 50% rest 31.4 °C( 89 °F ) 29.4 °C( 85 °F ) 27.9 °C( 82 °F )
25% work, 75% rest 32.2 °C( 90 °F ) 31.1 °C( 88 °F ) 30 °C( 86 °F )
Source : AGGIH 1992 ( The American Conference of
Governmental Industrial Hygienists )
WBGT INDEX and PHYSICAL EXERCISE)
WBGT Flag Activity Intensity
< 26.7 °C( < 80 °F ) White Normal activity.
Caution should be taken.
26.7 to 29.4 °C( 80 to 84.9 °F ) Green Descretion is required
in planning intense
physical activity.
29.5 to 31 °C
( 85 to 87.9 °F )
Yellow Intense activity for new and unacclimatized persons should be curtailed.
31.1 to 32.2 °C( 88 to 89.9 °F ) Red Intense exercise must be curtailed for those with less than 12 weeks training in hot weather. Be on high alert
≧ 32.2 °C( ≧ 90 °F ) Black Cancel all outdoor exercise.

Reviews

There are no reviews yet.

Be the first to review “HEAT INDEX WBGT METER-WBGT-2010SD”